Air Leakage Testing Machine (Single Cell in one go)
Air Leakage Tester Manual:
Operator has to Press Pneumatic Pressure Valve at preset pressure and watch Pressure Gauge for drop age of air pressure into one after another cell. Pressure valve is made of Aluminum that gives longer life. Pressure Gauge is Rubber guard so it is safe even if it is used carelessly.
This machine is used to perform air leakage testing automatically. In this machine, Battery is placed below the fixture, once cycle is initiated by any form of electrical initiation either touching a limit switch or crossing a beam or by pressing a push button.
In succession steps are performed, this operation initiate leakage fixture to close all the vents, system pressurizes 1, 3 & 5 cells to set pressure, & this pressure is holed for pre set period, pressure is switched off and monitored for drop in pressure by way of pressure switches if drops below set pressure respective pressure switch initiates fault signal by way of alarm or indication.
If this section is found with out leakage (pressure does not drop) then air pressure is released from 1, 3 & 5 cells and 2, 4 & 6 cells are pressurize and the same sequence follows.
In this automatic system so many discrepancies are avoided. In one go only, all above test are checked by cross-checking analogue meters.
This Machine is Available in Two Models: